Gas Chromatography - GC

Gas Chromatography - GC

Product Details:

  • Driven Type Electric
  • Frequency 50/60 Hz
  • Material Stainless Steel
  • Temperature Ambient to 400C
  • Size Standard
  • Weight 20-30 Kg Approx
  • Power 500 W
  • Click to view more
X

Gas Chromatography - GC Price And Quantity

  • 1 , , Number
  • Hydrogen, Nitrogen, Helium, Argon
  • USB, RS232, Ethernet
  • PC-based operation and reporting software
  • Temperature programmable, fast heat-up and cool-down
  • Up to 3 Simultaneous Channels
  • Full automation available with optional accessories
  • FID, TCD, ECD, FPD, NPD
  • Manual/Split/Splitless, Autosampler compatible

Gas Chromatography - GC Product Specifications

  • Chemical Analysis, Food & Beverage, Environmental Analysis, Petrochemical Industry, Pharmaceutical Industry
  • 50/60 Hz
  • 0.1 ppm to 100% (depending on detector and application)
  • Digital LCD Display
  • Stainless Steel
  • Electric
  • Standard
  • Ambient to 400C
  • 500 W
  • Digital
  • 220V AC
  • 20-30 Kg Approx
  • Hydrogen, Nitrogen, Helium, Argon
  • USB, RS232, Ethernet
  • PC-based operation and reporting software
  • Temperature programmable, fast heat-up and cool-down
  • Up to 3 Simultaneous Channels
  • Full automation available with optional accessories
  • FID, TCD, ECD, FPD, NPD
  • Manual/Split/Splitless, Autosampler compatible

Gas Chromatography - GC Trade Information

  • MUMBAI
  • Cheque, Cash in Advance (CID)
  • 1000 , , Number Per Month
  • 4 Days
  • Yes
  • Contact us for information regarding our sample policy
  • 5 gms Sample
  • Dadra and Nagar Haveli, Andaman and Nicobar Islands, Pondicherry, Uttarakhand, Daman and Diu, North India, Haryana, East India, South India, Jharkhand, Andhra Pradesh, Rajasthan, Tripura, Central India, Maharashtra, Madhya Pradesh, Manipur, Telangana, Kerala, Punjab, Chandigarh, Jammu and Kashmir, Mizoram, Gujarat, Nagaland, Karnataka, Sikkim, Tamil Nadu, Lakshadweep, Delhi, West Bengal, Bihar, Meghalaya, Assam, Odisha, Arunachal Pradesh, Goa, Himachal Pradesh, West India, Chhattisgarh, Uttar Pradesh, All India
  • ISO 9001:2015

Product Description

Gas Chromatography (GC)

Gas Chromatography- Head Space (GC-HS)

  • Purity / Impurity Profiling
  • Fatty Acid Methyl Esters
  • Method Development / Method Validation
  • Quantification of Organic Volatile Impurities / Residual Solvents by Head Space.


Versatile Detector Support

Choose from a variety of detectors, such as FID, TCD, ECD, FPD, and NPD, to tailor the analysis according to your samples requirements. This flexibility allows users to address diverse analytical challenges across industries seamlessly.


Programmable Column Oven

The GC features a temperature-programmable oven ranging from ambient temperature up to 400C. Its fast heating and cooling rates enable quicker run times, supporting both method development and routine analysis efficiently.


Advanced Data Management

With multiple data output options, including USB, RS232, and Ethernet, users can easily integrate the GC with PC-based software for comprehensive operation and reporting. This integration enhances data accuracy and simplifies workflow management.

FAQs of Gas Chromatography - GC:


Q: How does the Gas Chromatography system accommodate diverse sample types and analyses?

A: Our GC system offers up to three simultaneous channels and supports multiple detectors (FID, TCD, ECD, FPD, NPD), making it suitable for a broad spectrum of applications in chemical, environmental, food & beverage, petrochemical, and pharmaceutical industries.

Q: What options are available for injecting samples into the GC?

A: Samples can be introduced using manual, split, splitless, or via an autosampler for automated, high-throughput operation, ensuring convenience regardless of your laboratorys throughput needs.

Q: When is it beneficial to utilize the temperature-programmable column oven?

A: The programmable oven is ideal when precise temperature control and rapid ramping are required, enhancing separation efficiency and reducing total analysis time, especially for volatile or complex mixtures.

Q: Where can this GC system be deployed?

A: Designed for laboratory use, this GC is a fit for research institutions, QC labs, and analytical service providers throughout India, especially those operating in regulated industries or requiring robust analytical capability.

Q: What is the process for automating GC operations?

A: Full automation can be achieved by integrating optional accessories such as an autosampler, allowing for unattended, sequential sample analysis and maximizing productivity.

Q: How does the digital interface and software benefit users?

A: The digital LCD display, combined with intuitive PC-based software, provides real-time status, simple method setup, and comprehensive reporting, thereby streamlining data management and reducing the potential for human error.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail