Surface Tension by Surface Tensiometer

Surface Tension by Surface Tensiometer

Product Details:

  • Usage & Applications Measurement of surface tension in liquids for laboratory and research purposes
  • Size Standard
  • Display Digital LCD
  • Temperature Ambient (operational at 10C to 40C)
  • Power 20W
  • Material Stainless Steel
  • Interface Analog/Digital
  • Click to view more
X

Surface Tension by Surface Tensiometer Price And Quantity

  • 1 Unit
  • Corrosion-resistant coating
  • Standard weight set, calibration certificate, power cable
  • Continuous and single sample modes
  • Interchangeable clamps for diverse sample sizes
  • Automatic and manual calibration available
  • 0.01 mN/m
  • USB and RS232 connectivity
  • ISO 304 standard certified
  • ±0.1 mN/m
  • <2 seconds

Surface Tension by Surface Tensiometer Product Specifications

  • 0 to 1000 mN/m
  • Stainless Steel
  • Analog/Digital
  • 20W
  • 50 Hz
  • Ambient (operational at 10C to 40C)
  • Manual/Electrical
  • 220V AC
  • Standard
  • Digital LCD
  • Approx. 2 Kg
  • Measurement of surface tension in liquids for laboratory and research purposes
  • Corrosion-resistant coating
  • Standard weight set, calibration certificate, power cable
  • Continuous and single sample modes
  • Interchangeable clamps for diverse sample sizes
  • Automatic and manual calibration available
  • 0.01 mN/m
  • USB and RS232 connectivity
  • ISO 304 standard certified
  • ±0.1 mN/m
  • <2 seconds

Surface Tension by Surface Tensiometer Trade Information

  • Cash on Delivery (COD), Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • 1000 Unit Per Month
  • 4-10 Days
  • Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa, Asia
  • All India

Product Description



Spotlight your research with the advanced Surface Tension by Surface Tensiometer, featuring enviable accuracy of 0.1 mN/m and an unparalleled resolution of 0.01 mN/m. This renowned instrument offers both automatic and manual calibration, ensuring reliable results every time. Interchangeable clamps accommodate diverse sample sizes, complemented by USB and RS232 data output for seamless integration. Its robust stainless steel construction boasts a corrosion-resistant finish, while the digital LCD display and rapid response time (<2 seconds) streamline laboratory workflows. ISO 304 certified and complete with essential accessories, this promotion ensures unprecedented measuring confidence.

Targeted Application and Usage Versatility

The Surface Tension by Surface Tensiometer employs continuous and single sample operating modes, making it ideal for research and laboratory measurement of liquid surface tension. Users benefit from its adaptable application methods and interchangeable sample holders, suitable for various sample sizes. Designed for both educational and industrial laboratory settings, it enables accurate analysis for a broad spectrum of liquid substances, enhancing experimentation and quality control initiatives with ease.


Certifications, Sample Policy, and Payment Terms

Certified to ISO 304 standards, this Surface Tensiometer assures compliance and reliability. Packing & dispatch procedures are meticulously managed, with quick dispatch and secure transportation options readily available. Each order includes a calibration certificate and standard weight set. Sample policy details and payment terms are communicated transparently, with various options to meet customer requirements, ensuring a seamless acquisition process from order confirmation to final delivery.


FAQs of Surface Tension by Surface Tensiometer:


Q: How does the Surface Tension by Surface Tensiometer achieve such accurate readings?

A: The device utilizes high-resolution sensors and offers both automatic and manual calibration, ensuring consistent accuracy (0.1 mN/m) across a measuring range of 0 to 1000 mN/m.

Q: What sample types can be measured with this instrument?

A: Thanks to its interchangeable clamps, the tensiometer handles diverse sample sizes and is suitable for most liquid samples encountered in laboratory and research settings.

Q: When should I perform calibration?

A: Calibration can be carried out either automatically or manually. Its recommended to calibrate before each measuring session or as specified by your laboratorys standard operating procedures for optimal accuracy.

Q: Where does the USB and RS232 data output come into play?

A: Both USB and RS232 interfaces enable seamless transfer of measurement data to digital systems or external devices, streamlining analysis, documentation, and reporting.

Q: What are the benefits of ISO 304 compliance?

A: ISO 304 certification ensures the tensiometer adheres to internationally recognized standards for accuracy, reliability, and quality, providing confidence in measurement results for research or industrial applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Instrumental Analysis' category



Back to top